24 changes: 24 additions & 0 deletions docs/changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -28,6 +28,26 @@ _In development._
Thanks to [Jan Kundrát](https://github.com/jktjkt) for reporting the issue along
with a proposed fix ([PR #6](https://github.com/gertvdijk/PyKMP/pull/6)).

- The catalog of units and registers in [`pykmp.constants`][pykmp.constants] has been
expanded substantially:

- The [register display names][pykmp.constants.REGISTERS] catalog has been expanded
for an **additional 108 register IDs**. 90 of which were found on MULTICAL® 603
and MULTICAL® 303 meters and 18 on the 382 electricity meter.
- Eight new unit IDs have been added to the
[unit display names mapping][pykmp.constants.UNITS_NAMES].
- Several unit display names have been corrected and extended, including fixes for
Kelvin and for watt- and var-based units.
- A few register display names have been refined with clearer suffixes to denote the
'channel'.

Thanks to [Jan Kundrát](https://github.com/jktjkt) for contributing the extensive
list of the MULTICAL® heat meter additions along with a proposed change
([PR #4](https://github.com/gertvdijk/PyKMP/pull/4)).

Thanks to [Benny Lyne Amorsen](https://github.com/amorsen) for listing the registers
on the electricity meter.

### Tooling changes

- Project documentation has been migrated from [MkDocs](https://www.mkdocs.org/) with
Expand All @@ -37,6 +57,10 @@ _In development._

### Development changes

- The [`constants`][pykmp.constants] module now uses decimal IDs for
[`REGISTERS`][pykmp.constants.REGISTERS] and
[`UNITS_NAMES`][pykmp.constants.UNITS_NAMES], matching the primary numbering used in
vendor documentation and the tool's default output more closely.
- Pyright has been adopted as an additional strict type checker in `run-all-linters`,
with configuration aligned more closely with the VS Code IDE experience.
- Binary-heavy tests and related constants have been reformatted to use
Expand Down
320 changes: 222 additions & 98 deletions src/pykmp/constants.py
Original file line number Diff line number Diff line change
Expand Up @@ -14,109 +14,233 @@
from typing import Final # pragma: no cover


# Decimals of each variable in the GetRegister command request/response (CID=0x10)
# Register display names as used with GetRegister command request/response (CID=0x10)
REGISTERS: Final[Mapping[int, str]] = {
0x003C: "Heat Energy (E1)",
0x0044: "Volume",
0x004A: "Flow",
0x0050: "Current Power",
0x0056: "Temp1",
0x0057: "Temp2",
0x0059: "Tempdiff",
0x0061: "Temp1xm3",
0x006E: "Temp2xm3",
0x0071: "Infoevent",
0x007B: "MaxFlowDate_Y",
0x007C: "MaxFlow_Y",
0x007D: "MinFlowDate_Y",
0x007E: "MinFlow_Y",
0x007F: "MaxPowerDate_Y",
0x0080: "MaxPower_Y",
0x0081: "MinPowerDate_Y",
0x0082: "MinPower_Y",
0x008A: "MaxFlowDate_M",
0x008B: "MaxFlow_M",
0x008C: "MinFlowDate_M",
0x008D: "MinFlow_M",
0x008E: "MaxPowerDate_M",
0x008F: "MaxPower_M",
0x0090: "MinPowerDate_M",
0x0091: "MinPower_M",
0x0092: "AvgTemp1_Y",
0x0093: "AvgTemp2_Y",
0x0095: "AvgTemp1_M",
0x0096: "AvgTemp2_M",
0x010A: "E1HighRes",
0x03EC: "HourCounter",
1: "Energy in",
2: "Energy out",
13: "Energy in hires",
14: "Energy out hires",
60: "Heat Energy (E1)",
61: "Inlet Energy E4",
62: "Outlet Energy E5",
63: "Cooling Energy E3",
64: "Tariff TA2",
65: "Tariff TA3",
66: "Tariff limit 2",
67: "Tariff limit 3",
68: "Volume V1",
69: "Volume V2",
72: "Mass M1",
73: "Mass M2",
74: "Flow V1",
75: "Flow V2",
80: "Current Power",
84: "Pulse input A1",
85: "Pulse input B1",
86: "Temp1",
87: "Temp2",
88: "Temp3",
89: "Tempdiff",
91: "Pressure P1",
92: "Pressure P2",
94: "Heat Energy E2",
95: "Tap water energy E6",
96: "Tap water energy E7",
97: "Temp1xm3 E8", # V1 * t1 (inlet)
98: "Target Date",
99: "InfoCode",
104: "Meter number for VB",
110: "Temp2xm3 E9", # V2 * t2 (outlet)
112: "Customer number 2", # 8 most-significant digits
113: "Infoevent",
114: "Meter number for VA",
122: "Temp4",
123: "MaxFlowDate_Y",
124: "MaxFlow_Y",
125: "MinFlowDate_Y",
126: "MinFlow_Y",
127: "MaxPowerDate_Y",
128: "MaxPower_Y",
129: "MinPowerDate_Y",
130: "MinPower_Y",
138: "MaxFlowDate_M",
139: "MaxFlow_M",
140: "MinFlowDate_M",
141: "MinFlow_M",
142: "MaxPowerDate_M",
143: "MaxPower_M",
144: "MinPowerDate_M",
145: "MinPower_M",
146: "AvgTemp1_Y",
147: "AvgTemp2_Y",
149: "AvgTemp1_M",
150: "AvgTemp2_M",
152: "Program number", # not seen on meters: ABCCCCCC
153: "Config number 1", # config no. DDDEE
154: "Software Checksum 1",
168: "Config number 2", # config no. FFGGMN
175: "Error hour counter",
178: "Differential energy dE",
179: "Control energy cE",
180: "Differential volume dV",
181: "Control volume cV",
# 183: looks like a meter S/N on Multical 603
184: "MbusPriAdrMod1",
185: "MbusSekAdrMod1",
218: "MbusPriAdrMod2",
219: "MbusSekAdrMod2",
222: "ConfigChangedEventCount",
224: "Pulse input A2",
225: "Pulse input B2",
228: "Config number 3",
229: "T1_average_autoint",
230: "T2_average_autoint",
234: "l/imp for VA",
235: "l/imp for VB",
239: "Volume V1 hires",
# Undocumented (259 and 260), but it matches the info given by Multical 603 in the
# diagnostics display
259: "Nominal Q\N{LATIN SUBSCRIPT SMALL LETTER P} V1",
260: "Nominal Q\N{LATIN SUBSCRIPT SMALL LETTER P} V2",
266: "E1HighRes",
267: "Cooling energy E3 hires",
346: "Module SW rev",
347: "Customer number",
348: "Date and Time", # TODO: unknown unit 79, 28591984415535
355: "COP Year",
362: "Tariff TA4",
364: "Heat energy A1", # Heat energy with discount A1, t2 < t5 limit
365: "Heat energy A2", # Heat energy with surcharge A2, t2 > t5 limit
366: "T5 limit",
367: "COP Month",
368: "Config number 4",
369: "Info bits",
371: "COP",
372: "Power input B1",
379: "T1 time average day",
380: "T2 time average day",
381: "T1 time average hour",
382: "T2 time average hour",
383: "Flow V1 max year date",
# 384: something similar as 383?
385: "Power max year date",
# 386: something similar as 385?
387: "Flow V1 max month date",
# 388: something similar as 387?
389: "Power max month date",
# 390: something similar as 389?
398: "T1 actual (one decimal)",
399: "T2 actual (one decimal)",
400: "T1-T2 (one decimal)", # Undocumented, but appears as such on Multical 603
404: "Meter Type",
473: "Energy E10",
474: "Energy E11",
477: "T3 time average day",
478: "T3 time average hour",
505: "P1 average day",
506: "P2 average day",
507: "P1 average hour",
508: "P2 average hour",
# Undocumented, but it matches the actual interval on Multical 303
675: "wM-Bus transmission interval",
1001: "Fabrication No",
1002: "Time",
1003: "Date",
1004: "HourCounter",
1005: "Software edition",
1010: "Customer number 1", # 8 least-significant digits
1023: "Power in",
1024: "Power out",
1032: "Operation Mode",
1054: "Voltage L1",
1055: "Voltage L2",
1056: "Voltage L3",
1076: "Current L1",
1077: "Current L2",
1078: "Current L3",
1080: "Power in L1",
1081: "Power in L2",
1082: "Power in L3",
1344: "Power out L1",
1345: "Power out L2",
1346: "Power out L3",
}


UNITS_NAMES: Final[Mapping[int, str]] = {
0x00: "no unit (number)",
0x01: "Wh",
0x02: "kWh",
0x03: "MWh",
0x04: "GWh",
0x05: "J",
0x06: "kJ",
0x07: "MJ",
0x08: "GJ",
0x09: "Cal",
0x0A: "kCal",
0x0B: "Mcal",
0x0C: "Gcal",
0x0D: "varh",
0x0E: "kvarh",
0x0F: "Mvarh",
0x10: "Gvarh",
0x11: "VAh",
0x12: "kVAh",
0x13: "MVAh",
0x14: "GVAh",
0x15: "kW",
0x16: "kW",
0x17: "MW",
0x18: "GW",
0x19: "kvar",
0x1A: "kvar",
0x1B: "Mvar",
0x1C: "Gvar",
0x1D: "VA",
0x1E: "kVA",
0x1F: "MVA",
0x20: "GVA",
0x21: "V",
0x22: "A",
0x23: "kV",
0x24: "kA",
0x25: "°C",
0x26: "°K",
0x27: "l",
0x28: "m³",
0x29: "l/h",
0x2A: "m³/h",
0x2B: "m³\N{MULTIPLICATION SIGN}C",
0x2C: "ton",
0x2D: "ton/h",
0x2E: "h",
0x2F: "hh:mm:ss",
0x30: "yy:mm:dd",
0x31: "yyyy:mm:dd",
0x32: "mm:dd",
0x33: "no unit (number)",
0x34: "bar",
0x35: "RTC",
0x36: "ASCII",
0x37: "m³ \N{MULTIPLICATION SIGN}10",
0x38: "ton \N{MULTIPLICATION SIGN}10",
0x39: "GJ \N{MULTIPLICATION SIGN}10",
0x3A: "minutes",
0x3B: "Bitfield",
0x3C: "s",
0x3D: "ms",
0x3E: "days",
0x3F: "RTC-Q",
0x40: "Datetime",
0: "no unit (number)",
1: "Wh",
2: "kWh",
3: "MWh",
4: "GWh",
5: "J",
6: "kJ",
7: "MJ",
8: "GJ",
9: "Cal",
10: "kCal",
11: "Mcal",
12: "Gcal",
13: "varh",
14: "kvarh",
15: "Mvarh",
16: "Gvarh",
17: "VAh",
18: "kVAh",
19: "MVAh",
20: "GVAh",
21: "W",
22: "kW",
23: "MW",
24: "GW",
25: "var",
26: "kvar",
27: "Mvar",
28: "Gvar",
29: "VA",
30: "kVA",
31: "MVA",
32: "GVA",
33: "V",
34: "A",
35: "kV",
36: "kA",
37: "°C",
38: "K",
39: "l",
40: "m³",
41: "l/h",
42: "m³/h",
43: "m³\N{MULTIPLICATION SIGN}C",
44: "ton",
45: "ton/h",
46: "h",
47: "hh:mm:ss",
48: "yy:mm:dd",
49: "yyyy:mm:dd",
50: "mm:dd",
51: "no unit (number)",
52: "bar",
53: "RTC",
54: "ASCII",
55: "m³ \N{MULTIPLICATION SIGN}10",
56: "ton \N{MULTIPLICATION SIGN}10",
57: "GJ \N{MULTIPLICATION SIGN}10",
58: "minutes",
59: "Bitfield",
60: "s",
61: "ms",
62: "days",
63: "RTC-Q",
64: "Datetime",
Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

you can also add:

  • 65: "imp/L", impulses per liter
  • 66: "L/imp", liters per impulse

Copy link
Copy Markdown
Owner Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Thanks! I'll adopt it lowercase as other liters are denoted with lowercase-l, is that OK?

Copy link
Copy Markdown
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

agreed

65: "imp/l",
66: "l/imp",
85: "%RH",
86: "%O\N{SUBSCRIPT TWO}",
87: "m/s",
88: "kJ/kg",
89: "pH",
90: "g/kg",
}


Expand Down